Direct Connect Oxygen Monitoring Detector head :
The Riken Keiki GD-F3-AA is a Detector Head with Direct connect sensor for use in Oxygen Monitoring applications. It Features a range of 0-25% Volume as well as having options for 0-50% volume. The GD-F3-AA is designed to be connected to the RM-5000 or RM-6000 Monitor panels. It has a Compact & light weight design and Splash-proof construction as well as being Intrinsically safe with a zener barrier.
Long lived and reliable
Low drift , accurate and long service life
Flexible for single and multipoint O2 applications
Allows for competitive multipoint Oxygen monitoring system construction
The GD-F3-AA provides a rugged cost effective solution to multi-point Oxygen Deficiency systems . The GD-F3-AA connects directly to the RM-5000 monitor panel to give reliable measurement of Oxygen levels in a multitude of large area applications such as Large confined spaces , plant rooms , Manufacturing facilities as well as Automotive test facilities .
It has a wide operating temperature range as low as -10 degrees C up to 40 Degrees C.
Proven Sensor Technology :
The Riken Keiki GD-F3-AA is based around Rikens tried and tested OS-B11 sensor . This sensor is used in many fixed systems worldwide and has been shown to provide stable as well as reliable service. The OS-B11 is based around Galvanic technology.
The Riken Keiki RM-5000 is a multi-channel Gas Monitor Panel. The RM-5000 is ideal for monitoring combustible gases and toxic gases as well as Oxygen. It is ideal for Multi point Oxygen Monitoring Systems in a range of industrial , Manufacturing applications
The RM-5000’s clever modular design allows for monitoring of 2 to 12 channels. The RM-5000 achieves this by simply by inserting indicator units to match the gas required. In addition a custom panel will accommodate up to 32 Channels. The modular indicator units slot into the case. Users then connect detector heads for Carbon Monoxide, Oxygen in addition to Combustible gases and other toxic gases. Detector heads that can be used include the SD-1 and also the GD-A80 , GD-F3-AA as well as the GD-70D Intelligent pumped gas monitors .
The Indicator units each have an independent digital display that is easy to read . Each Indicator has a bar meter and multi-colour display for ease of monitoring. Power consumption is very low. The RM-5000 is compatible with previous generation Riken Monitor Panels. The RM-6000 is available for single channel applications. The GD-F4-AA is available for sample draw applications.
Model | GD-F3-AA |
Detection Principal | Galvanic cell method |
Detectable Gas | Oxygen (O2) |
Detection Method | Diffusion |
Detection Range | 0-25% Vol |
Transmission Scheme | Direct output from sensor |
Transmission cable | CVVS worth of shield cable(1.25mm 2 )・2-core |
Transmission distance | Less than 600m by CVVS・1.25mm 2 cable |
Zener barrier | MTL7761Pac |
Cabling port | Cable gland(Suitable cable dia φ8~φ11mm) |
Operating temperature | -10~+40℃ (non-rapidly-vary. It may differ according to mounted sensor.) |
Operating Humidity | 90% RH or less ( Non condensing ) |
Structure | Wall mounting type/mountable to pipe size 2B<50A> |
Explosion-proof structure | Intrinsically safe structure(by using zener barrier) |
Explosion-proof grade | ExiaⅡCT4X |
Explosion-proof approval No | TC21279 (TIIS,Japan) |
Outer Dimensions / Weight | Approx.140(W)×175(H)×86(D)mm /approx.1.5kg |
Colour | Munsell 2.5Y9/2 semi-gloss |
We are able to provide products and advice usually within short timescales. For product advice, servicing and enquiries, please contact our experienced team: